Product Details:

Place of Origin: China
Brand Name: Hengli
Model Number: Type M-.SED10...L1X

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: Wooden packing
Delivery Time: 5-30 days upon order quantity
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 50 set / 30 days
Detailed Product Description
Material: C.S/SS Seal: NBR/FKM
Pressure: 350 Bar Max. Flow: 40 L/min
Fluid Temperature Range: -30 To +80 (NBR Seal)/-20 To +80 (FKM Seal) ℃
High Light:

hydraulic lever control valves

,

hydraulic proportional control valve

 

3/2 and 4/2 directional poppet valves with solenoid operation

Type M-.SED10...L1X

Features

- Direct operated directional poppet valve with solenoid actuation

- Mounting face as per DIN24 340 A

ISO 4401 and CETOP-RP 121H

- Closed port is leak-free isolated

- keep switch flexibility under high pressure

- Pressure-tight chamber does not need to be opened for a change of the coil

- Solenoid coil can be rotated through 90°

- With concealed manual override, optional

 

Function and configuration

·Type M-SED10 3/2 directional poppet valve

Directional valves of the type SED are direct operated directional poppet valves with solenoid actuation.

They control the start, stop and direction of flow.

The directional poppet valves consist of housing (1), the solenoid (2), the valve seat (7) and (11) and the control spool (4).

The manual override (6) allows for the switching of the valve without solenoid energization.

General principle (3/2 directional poppet valve):

The initial position of the valve (normally open "UK" or normally closed "CK") is determined by the arrangement of the spring (5). The chamber (3) behind the control spool(4) is connected to port P and sealed against port T. Thus, the valve is pressure compensated in relation to the actuating forces (solenoid and spring).

By means of the control spool (4),the port P,A and T can be loaded with maximum operating pressure (350bar) and the flow can be directed in both directions (see symbols).

In the initial position, the control spool (4) is pressed onto the seat (11) by the spring (5), in spool position, it is pressed onto the seat (7) by the solenoid (2). The flow is blocked.

Durable Hydraulic Control Valve Directional Poppet Valve With Solenoid Operation

·Type M-4SED10 4/2 directional poppet valve

With a sand with plate, the Plus-1plate, under the 3/2 directional poppet valves, the function of a 4/2 directional poppet valve is achieved.

1). Initial position:

the main valve is not actuated. The spring(5)holds the control spool(4)on the seat(11).Port P is blocked and A is connected to T. Apart from that, one control line is connected from A to the large area of the control spool(8), which is thus unloaded to the tank. The pressure applied via P now pushes the ball(9) onto the seat(10). Now, P is connected to B, and A to T.

2). Transition position:

When the main valve is actuated, the control spool(4) is shifted against the spring(5) and pressed onto the seat(7). During this, port T is blocked, P, A, and B are briefly connected to each other.

3). Spool position:

P is connected to A.As the pump pressure acts via A on the large area of the control spool (8), the ball (9) is pressed onto the seat (12). Thus, B is connected to T, and P to A. The ball (9) in the Plus-1 plate has a "positive spool overlap".

Durable Hydraulic Control Valve Directional Poppet Valve With Solenoid Operation

·Throttle insert:

The use of a throttle insert is required, if, due to the operating conditions, flows are to be expected during the switching procedure, which are higher than the started maximum performance limits of the valve.

The throttle is inserted into port P of the valve.

·Cartridge check valve:

The cartridge check valve allows free flow from P to A and provides leak-free closed from A to P.

The cartridge check valve is inserted into port P of the valve.

Durable Hydraulic Control Valve Directional Poppet Valve With Solenoid Operation

Spool symbols

Durable Hydraulic Control Valve Directional Poppet Valve With Solenoid Operation

 

Specification

Durable Hydraulic Control Valve Directional Poppet Valve With Solenoid Operation

 

Technical data

Installation position Optional
Environment temperature -30 to +50 (NBR seal)
-20 to +50 (FKM seal)
Weight Two tee Solenoidic directional valve Kg 2.6
Two four-way Solenoidic directional valve Kg 3.9
Max operation pressure bar 350
Max flow L/min 40
Hydraulic fluid Mineral oil suitable for NBR and FKM seal
Phosphate ester for FKM seal
Fluid temperature range -30 to +80 (NBR seal)
-20 to +80 (FKM seal)
Viscosity range mm2/s 2.8 to 500
Degree of contamination Maximum permissible degree of fluid contamination:Class 9. NAS 1638 or 20/18/15, ISO4406

 

Electrical data

Voltage type DC AC+ rectifier
Voltage version V 12, 24, 110, 205, 220 110,220(only possible via Z5 rectifier)
Permissible voltage(deviation) % +10~-15
Input power W 30
Continuous power-on time Continuous
Switching time to ISO 6403
Pressure bar Flow L/min DC solenoid AC + rectifier
On/ms (without oil tank pressure) Off/ms On/ms (without oil tank pressure) Off/ms
UK CK D Y UK, CK D, Y UK CK D Y UK, CK D, Y
70 40 40 30 40 35 10 10 35 30 40 35 40 40
140 40 40 30 40 35 10 10 40 30 40 35 40 40
210 40 45 35 45 35 10 10 45 35 45 35 40 40
280 40 45 35 45 35 10 10 45 35 45 35 40 40
315 40 50 35 50 35 10 10 50 40 50 35 40 40
350 40 50 45 50 45 10 10 50 45 50 45 40 40
Note: The switching types relate to a flow of P to A and A to T. With reversed flows deviations are possible.
Switching frequency Cycles/h to 15000
IP rating as per DIN 40050 IP65
Max coil temperature +150

Note: for electrical connection, protective wire (PE) shall be earthed as required.

 

Unit dimensions

·M-3SED10 -L1X/...solenoid directional poppet valve

Durable Hydraulic Control Valve Directional Poppet Valve With Solenoid Operation

1 Solenoid

2 Manual override

3 Plug-in connector to DIN 43650 (rotatable 90º)

4 Space required to remove the Plug-in connector

5 O-rings 12×2 for ports A,B,TA,TB

   O-rings 14×2 for port P

6.1 Plug for M-3SED10UK-L1X/

6.2 Plug for M-3SED10CK-L1X/

7 Name plate

8 Space required to remove the coil

9.1 Total length of M-3SED10UK-L1X/

9.2 Total length of M-3SED10CK-L1X/

10 Securing nut tighting torque MA = 4Nm

11 Ports B and TB are a blind counter bore

12 Valve fixing screws

     Internal hexagon screw: M6×40 GB/T 70.1-10.9,

     tighting torque MA = 15.5 Nm

It must be ordered separately, if connection plate is needed. Type:

G 66/01 (G 3/8), G 66/02 (M18×1.5)

G 67/01 (G 1/2), G 67/02 (M22×1.5)

 

·M-4SED10 -L1X/...solenoid directional poppet valve

Durable Hydraulic Control Valve Directional Poppet Valve With Solenoid Operation

1 Solenoid

2 Manual override

3 Plug-in connector to DIN 43650 (rotatable 90º)

4 Space required to remove the Plug-in connector

5 O-rings 12×2 for ports A,B,TA,TB

   O-rings 14×2 for port P

6.1 Plug for M-4SED10D-L1X/

6.2 Plug for M-4SED10Y-L1X/

7 Name plate

8 Space required to remove the coil

9.1 Total length of M-4SED10D-L1X

9.2 Total length of M-4SED10Y-L1X

10 Plus-1 Plate

11 Securing nut tighting torque MA = 4Nm

12 Port TB is a blind counter bore

13 Valve fixing screws

     Internal hexagon screw: M6×40 GB/T 70.1-10.9,

     tighting torque MA = 15.5 Nm

It must be ordered separately, if connection plate is needed. Type:

G 66/01 (G 3/8), G 66/02 (M18×1.5)

G 67/01 (G 1/2), G 67/02 (M22×1.5)

 

Contact Details
oepoch industrial technology

Contact Person: Shaohua

Send your inquiry directly to us (0 / 3000)