|
Product Details:
Payment & Shipping Terms:
|
Material: | C.S/SS | Seal: | NBR/FKM |
---|---|---|---|
Pressure: | 250 Bar | Max. Flow: | 14 L/min |
Fluid Temperature Range: | -30 To +50 (NBR Seal)/-20 To +50 (FKM Seal) ℃ | ||
High Light: | hydraulic lever control valves,hydraulic proportional control valve |
4-way 3-position, 4-way 2-position and 3-way 2-position directional valve with mechanical, manual operation
Type WE5...
Features
- Directional spool valve, direct operated by solenoid is the standard version
- Wet pin AC or DC solenoid
- Sub-plate mounting
Max. flow (L/min ) →
Spool symbol | Pressure rating (bar) | ||
50 | 100 | 250 | |
A, B, C, N, E, F, H, J, L, M, Q, R, U, W |
14 | 14 | 12 |
G | 10 | 10 | 9 |
Function and configuration
Type WE directional valves are wet pin AC or DC solenoid operated directional spool valves. They control the start, stop and direction of flow.
The directional valves mainly consist of housing (1), one or two solenoids (2), the control spool (3), one or two return springs (4).
When solenoid is de-energised, the control spool (3) is held by the return springs in the central position or initial position (except for impulse spool). The control spool is controlled by the wet pin solenoid (2). In order to ensure trouble-free functioning, care should be taken to ensure that the pressure chamber of the solenoid is filled with oil.
The control spool (3) is moved to the expected position by solenoid (2) and pushing rod (5), and this gives free-flow from P to A and B to T or P to B and A to T.
When solenoid (2) is de-energised, the control spool (3) is pushed to the initial position by the return spring (4).
The solenoids may also control the control spool (3) by an optional override button (6) under the de-energised condition.
Specifications
Note: If AC electric source is used, the "rectification AC" is recommended.
Symbols
Technical data
Fixing position | Optional | ||
Ambient temperature range | ℃ | -30 to +50 (NBR seal) | |
-20 to +50 (FKM seal) | |||
Weight | Valve | kg | 1.4 |
Sub-plate(G115/01A) | kg | 0.8 | |
Max.operating pressure | Port A,B,P | bar | 250 |
Port T | bar | 60, when the operating pressure exceed the permission value, port T must be used as drain port for spool symbol A and B | |
Max. flow-rate | L/min | 14 | |
Flow cross section (switching neutral position) | Type Q | mm2 | for symbol Q 6% of nominal cross section |
Type W | mm2 | for symbol W 3% of nominal cross section | |
Fluid | Mineral oil suitable for NBR and FKM seal | ||
Phosphate ester for FKM seal | |||
Fluid temperature range | ℃ | -30 to +80 (NBR seal) | |
-20 to +80 (FKM seal) | |||
Viscosity range | mm2/s | 2.8 to 500 | |
Degree of contamination | Maximum permissible degree of fluid contamination: Class 9. NAS 1638 or 20/18/15, ISO4406 |
Electrical data
Type of voltage | DC | AC 50Hz | ||
Usable voltage | V | 12,24,48,96; 110,205,220 | 110,127,220 | |
permissible voltage(deviation) | % | +10~ -15 | ||
Input power | W | 26 | – | |
Current | VA | – | 46 | |
Impact current | VA | – | 130 | |
Duty | Continuous working | |||
Switched time Accord with ISO 6403 | Open | ms | 40 | 25 |
Closed | ms | 30 | 20 | |
Switched frequency | times/h | to 15000 | to 7200 | |
Preventive grade according to DIN 40050 | IP65 | |||
Max. coils temperature | ℃ | 150 |
Caution: with electrical connections the protective conductor must be connected according to the relevant regulations.
Unit dimensions (Dimensions in mm)
Spool symbol E, F, G, H, J, L, M, Q, R, U, W are controlled by double-ended solenoids
1 Except reduction the dimension of one solenoid for 2-position, the others is the same as the 3-position valve.
2 O-ring 7×1.5
3 Valve mounting screws: M5×50 GB/T 70.1-10.9,
Tightening torque, MA =9Nm
must be ordered separately.
It must be ordered separately, if connection plate is needed. Type:
G115/01A(G1/4), G115/02A(M14×1.5)
Unit dimensions: connection sub-plate (Dimensions in mm)
Type | D1 | Valve fixing screws | Weight(kg) |
G115/01A | G1/4 | M5×50 GB/T70.1-10.9 | 0.7 |
G115/02A | M14×1.5 | M5×50 GB/T70.1-10.9 | 0.7 |